Download Secure Premier 300 Energy Meter Manual

Posted on
Energy

PILOT SPM91 with RS485 single phase smart energy meter Basic Function Suit for 230V & 120V AC low voltage system Measure and display U, I, P, kWh 6 +1 digits LCD display (999999.9 kWh) LED indicates pulse output Password protection One key for up/down page, one key for programming Small size: 100.36.65mm RS485 port, MODBUS-RTU communication protocol 35mm DIN rail installing, standard DIN ED5002 Standard: IEC62053-21 Technical Specification Order Information Packaging & Shipping Some of Our Factory Certificates. About product and suppliers:Alibaba.com offers 5,735 energy meter with rs485 products. About 75% of these are energy meters, 13% are power meters, and 3% are flow meters.A wide variety of energy meter with rs485 options are available to you, such as digital only, analog and digital, and analog only. You can also choose from single phase, three phase.

As well as from free samples, paid samples.There are 5,727 energy meter with rs485 suppliers, mainly located in Asia. The top supplying countries or regions are China, Hong Kong S.A.R., and Taiwan, China, which supply 97%, 1%, and 1% of energy meter with rs485 respectively.Energy meter with rs485 products are most popular in Southeast Asia, Domestic Market, and Western Europe.You can ensure product safety by selecting from certified suppliers, including 5,735 with ISO9001, 1,997 with ISO14001, and 1,194 with OHSAS18001 certification.

  • Or point us to the URL where the manual is located. Your manual failed to upload. Please try again.
  • Premier 300 CT/VT operated energy meter Accurate & interoperable comms with advance event detection for LV, MV & HV metering Premier is the family of CT/VT operated meters, which covers a wide range of power levels and offers flexible time-of-use tariff metering and communications capabilities.

Premie 300 User Manual (secure),bgx501-747-r04

Download Secure Premier 300 Energy Meter Manual

1 x 12 V (A23, LR23) Alkaline (cordless remote) Declaration of Conformity Doro hereby declares that Doro Secure 350 conforms to the essential requirements and other relevant regulations contained in the Directives 1999/5/EC (R&TTE) and 2002/95/EC (RoHS). A copy of the Declaration of Conformity is available at.

Premier 300 Interoperable Three-phase DLMS MeterUser Manual BGX501-747-R04Copyright © 2010-2012, Secure International Holdings Pte. All rights reserved. Premier 300® is a registered trade name of Secure Meters Ltd. Other product names are trade names or registered trademarks of their respective owners.Page 2 of 41BGX501-747-R04, Premier 300 User ManualPUBLICTable of Contents 1 Important. 5 2 Disclaimer. 5 3 Precautions and Safety Practices.

7 4 Deliverables. 8 5 Common Acronyms Used.

9 6 Introduction. 10 7 General Specifications. 11 8 External Features. 12 9 Using the Display.

14 9.1 Push-Button Details. 20 9.1.1Push-Button Mode. 209.1.2Auto mode.

209.2 Premier 300 physical dimensions. 21 9.3 Connection Diagrams.

2110 Premier 300 Installation. 23 10.1 Preparing for Installation. 23 10.1.1Selecting an appropriate mounting location. 2410.1.2Selecting suitable mounting screws. 2410.1.3Required tools and accessories.

2410.2 Premier 300 installation procedure. 25 10.2.1Groundwork. 2510.2.2Mounting the Premier 300.

2510.2.3Preparing cables for termination. 2610.2.4Making connections. 2611 Energy, Demand and Time Management.

30 11.1 Energy Types. 31 11.2 Fraud Metering. 32 11.3 STOD/TOU. 33 11.4 MD Reset. 33 11.5 Power-off duration, Tamper count. 33 11.6 Billing.

33 11.7 Maximum demand. 34 11.7.1Method of MD Calculation.

3411.8 Metrological output. 34 11.9 Time set. 3412 Event Logging.

35 12.1 Event Categories. 35 PUBLICBGX501-747-R04, Premier 300 User ManualPage 3 of 4112.2 Event support. 36 12.3 Self diagnostic features. 3713 External Communication.

38 13.1 Active mode. 38 13.1.1Meter readings – Instantaneous session. 3813.1.2Meter readings – Readings session. 3813.1.3Meter readings – Load survey session. 3813.1.4Meter readings – Events session. 3813.1.5Load survey / Interval data. 3813.2 Security.

38 13.3 Sub-active (SA) Mode. 3914 Notes. 40Page 4 of 41BGX501-747-R04, Premier 300 User ManualPUBLIC1 Important 1. As a result of our continuous efforts to improve our products, the specifications mentioned in this manual may be subject to change.

Therefore the availability of features may depend on the product variant. The specifications and features listed in this manual were correct when this document was released but may be subject to change and should be considered to be definitive. Please refer any queries to our sales team. No part of this manual or its contents may be published, distributed, scanned or copied, in electronic form or otherwise, without prior written consent of Secure Meters Ltd.

While we have made every effort to minimise errors, some may exist. We request feedback from users in this regard and undertake to correct such errors wherever possible. Secure Meters Ltd.

Reserves the right to alter the features or specifications mentioned in this document without prior notice. Please direct queries on our products or services to our sales team.

In most countries, electrical installations must comply with one or more sets of regulations issued by national authorities or by recognized local or international bodies. Such regulations must be adhered to, even if they are not referred to directly in this document. We conduct rigorous testing during the design and manufacture of our products to ensure that they comply with appropriate standards. There is no maintenance, repair or adjustment intended for this meter. There are no interchangeable or serviceable parts. The meter is intended to be installed in a mechanical environment ‘M1’, with shock and vibrations of low significance.2 Disclaimer Secure Meters Ltd. Assumes no responsibility for damage arising from misuse of our products such as, but not limited to, the following: 1.

Incomplete or incorrect installation or maintenance 2. Connection to incorrect voltage sources 3. Damaged insulation on connecting cables 4.

Contact with hazardous substances 5. Powerpoint password recovery key rapidshare. Immersion in water or any other liquid 6. Handling by unauthorized personsPUBLICBGX501-747-R04, Premier 300 User ManualPage 5 of 417. Handling by inebriated, intoxicated or mentally unbalanced personsPage 6 of 41BGX501-747-R04, Premier 300 User ManualPUBLIC3 Precautions and Safety Practices 1.

Energy meters are generally installed in electrically live surroundings. To minimise the risk of electrical shock, stay away from loose or exposed electrical connections. If there is loose or exposed electrical wiring near the installation site, initiate appropriate preventive measures.

Secure Premier 300 Wiring Diagram

Check for the wiring configuration of the meter and ensure that the meter is installed for the appropriate wiring connection. Before energizing the meter, ensure that no stray strands of wire are present outside the connector blocks.

Energy

Meter must be protected by fuses or voltage isolating links in each voltage circuit. Under no circumstances should the current transformer (CT) connections to the meter be disconnected while current is flowing in the primary circuit of the external CT.

Ensure that the connected load does not exceed the current range specified on the rating plate. The meter contains a battery that must be disposed of in a suitable manner at the end of its life. Secure Meters recommends carrying out regular installation checks, especially when the product is installed at locations posing higher risk of degradation or corrosion – such as under direct, strong sunlight, areas with high ambient temperature and little ventilation, areas near heat sources like a furnace, areas near sea or a water body, areas where the meter is regularly exposed to chemical fumes, etc. It is recommended to immediately cut off the meter supply upon occurrence of any fault within the meter. Keep the meter away from fire, corrosive chemicals, and fumes thereof, rain and direct, prolonged exposure to water.