Johnson Controls Serial Number Nomenclature Examples
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.Age of heating equipment & Systems:How to determine the age of your heating system and components.
Predator® Model Number Nomenclature 3 to 12.5 Ton Single Package Additional Options. These four digits will not be assigned until a quote is requested, or an order placed. Johnson Controller UNT 1126 (N2 protocol), DFS, APS Airflow Voltage. Johnson Controls Unitary Products 335691-YSD-C-0509 COOLING PERFORMANCE TOTAL CAPACITY. IUPAC nomenclature of organic compounds. Methods of conventional controls and application of static controls. Rothans & Associates specializes in coding and billing reimbursement for dental offices nationwide. Our number one goal is to ensure the success of your Dental. Phosphatidylinositol is one of a number of. The nomenclature used in. York Serial Numbers ID. NEW SERIAL NUMBER NOMENCLATURE. Example: Year Position #2 Position #4.
The neglected duty pdf. Here we provide several excellent sources for de-coding the data tag information on heating equipment.This article provides documents that explain and translate all of the data found on information tags and stickers used onheating & heat pump equipment, including equipment age, heating capacity, electrical requirements, and operating characteristics.We also provide a to this topic, or you can try the page top or bottom as a quick way to find information you need. Heating System Equipment Age - Guides for Reading HVAC & Water Heater Equipment Data Tags & Serial NumbersIf you don't know whether your heat is provided by a furnace (hot air) or boiler (hot water), or whether your fuel is oil, gas, or electric,and whether your heat is hot water, steam, or warm air,see.Then return to this page for help finding the equipment's age or date of manufacture. Five HVAC Heating & Air Conditioning Equipment Age & Data Tag DecodersOur photo shows data tags on a Weil McLain gas fired heating boiler that was manufactured on. Click to enlarge any imageWe found the boiler age by de-coding the boiler's CP/serial number code on the white sticker just above the data tag. Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator.
Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211. is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents).120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email:. The firm provides professional & &.
Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home.
York hvac had two different serial numbers for 1971 through 2004 and 2005 through the present day.Old Serial Number from 1971 – October, 2004Old Serial Number format look like this: XBFM220710, EADM203490, and BKJM310394.New Serial Number from October, 2004 to the present dayNew serial number format looks like this. W0E4298223, N0D6941103, and A0E5219381.Click the link in the bottom of the pages for questionHere how to read the old serial number: X B F M 2207101st digits X is the plant. X was made in MexicanA = AddisonB = BlackvilleC = CanadaD = MedinaE = ElyriaM = Mad’villeN = NormanW = WichitaX = MexicoY = York2nd digits B are the month.
B is in FebruaryA = JanuaryB = FebruaryC = MarchD = AprilE = MayF = JuneG = JulyH = August“I” was skipped“J” was skippedK = SeptemberL = OctoberM = NovemberN = December3rd digits F are the year. F is in 1976 or 1997A = 1971 or 1992B = 1972 or 1993C = 1973 or 1994D = 1974 or 1995E = 1975 or 1996F = 1976 or 1997G = 1977 or 1998H = 1978 or 1999“I” was skippedJ = 1979 or 2000K = 1980 or 2001L = 1981 or 2002M = 1982 or 2003N = 1983 or 2004(The month October, November, and December does not count with 2004)“O” was skippedP = 1984“Q” was skippedR = 1985S = 1986T = 1987“U” was skippedV = 1988W = 1989X = 1990Y = 19914th digits M are the TYPES OF ITEM. M is Basic unitsM = Mfg. Basic UnitP = Purchased Basic UnitS = Mfg.
Low Side ItemT = Purchased Low Side ItemY = Mfg. AccessoryZ = Purchased AccessoryO = FillerThe last 6 numbersIs the SEQUENCED NUMBERSHere how to read the New serial number: W 0 E 4 298223York New Serial Number - October, 2004 to the present dayHere how to read the new serial number: W 0 E 4 2982231st digits W are Manufacturing Plant.

This unit was made in WichitaN = NormanW = WichitaA = ApodacaS = Source One2nd and 4th digits 0 and 4 (number) is the year of manufacture.To find the year of manufacture you have to combine the 2nd digits with the 4th digits.Ex. W 0 E 4 298223 was made in 2004. W 0 E 6 298223 was made in 2006. W 1 E 0 298223 was made in 2010.More examples:If the 2nd and 4th digits look like this:2nd digits = 0 and the 4th digits is 5 = 200507 = 200711 = 20113rd digits E are the month. E is MayA = JanuaryB = FebruaryC = MarchD = AprilE = MayF = JuneG = JulyH = August“I” was skipped“J” was skippedK = SeptemberL = OctoberM = NovemberN = DecemberSorry everyone, I misplace MODEL NUMBER INFO - It Not Here; I can't find it!The last 6 numbersIs the SEQUENTIAL NUMBERSThis is the place to ask question on York serial and model number. Click the links below to ask question.
RatingPerformance &Physical Data of York Split Heat Pumps NEWby: MerlinI have the following York split unit heat pumps which I can't find the performance and physical data in the internet.1. 2TWA3048A30004AS/N 9052WF24F, Outdoor Unit2a. N4AHD16A06AS/N EBES036128, Fan Section Indoor Unit?2b. G/HC048SBS/N EHDS231145 Coil Section Indoor Unit?3.
Hvac Serial Number Nomenclature
F1RP036N06AS/N ELDS279750 Indoor UnitFrom site visit, 2a-2b, or 3 is paired with outdoor unit frim other manufacturer. RatingPerformance &Physical Data of York Split Heat Pumps NEWby: MerlinI have the following York split unit heat pumps which I can't find the performance and physical data in the internet.1. 2TWA3048A30004AS/N 9052WF24F, Outdoor Unit2a. N4AHD16A06AS/N EBES036128, Fan Section Indoor Unit?2b. G/HC048SBS/N EHDS231145 Coil Section Indoor Unit?3. F1RP036N06AS/N ELDS279750 Indoor UnitFrom site visit, 2a-2b, or 3 is paired with outdoor unit frim other manufacturer. RatingPerformance &Physical Data of York Split Heat Pumps NEWby: MerlinI have the following York split unit heat pumps which I can't find the performance and physical data in the internet.1.
2TWA3048A30004AS/N 9052WF24F, Outdoor Unit2a. N4AHD16A06AS/N EBES036128, Fan Section Indoor Unit?2b.
G/HC048SBS/N EHDS231145 Coil Section Indoor Unit?3. F1RP036N06AS/N ELDS279750 Indoor UnitFrom site visit, 2a-2b, or 3 is paired with outdoor unit frim other manufacturer. RatingIdentify my unit NEWby: willem bezemeri have an older furnace, newish compressor 4ton.cannot find nameplate on furnace. But do have the following; label#1conversion kit;1n0347-propane, p2mp/pbkm series, p2dp/pbkd(2-5cell), 035-10853 000 rev a. Label#2, p2mpd 6no64 01c,272,1489-41. Label#3, diagnostic indicator.
Continues light.! Flash=replace control, 2flash=lockout-check furnace, 3 flash=pressure switch stuck closed, 4 flash=pressure switch stuck open, 5 flash= open limit, continues flshes= flame-nocall for heat. 035-11259-000 rev a.
Can you identify the model etc, by these stickers? Email willembezemer@att.net Home no. 713 868 5187, wife cell 713 582 2472 I used to be in a/c engineering with Grunewald Engineering (deceased) Your local eng. Rep may be able to help me.His/her name, tel no. Would be appreciated. Willem Bezemer.
Ratinginfo requestedby: AnonymousWARRANTY CENTER Warranty Verification Unit DetailsSerial Number: Model Number: Description: Unit Status:WBMM002264 H4DB036S06 3.0T 10S AC R22 ActiveDistribution Channel Status: Shipped to DistributorLatest Date On Record: 02/13/03The Unit is not registered with an Install Date.WARRANTY CENTER Warranty Verification Standard Warranty CoverageCoverage Type: Terms: Expiration Date:Labor: 030 Days 03/15/03Parts: 060 Months 02/13/08Compressor: 060 Months 02/13/08. RatingCondensor Problemby: AnonymousHi I have a Carrier System the Condensor Unit S#1004E33130 Model #38TA042My Coil is Carrier Model#CK5AXA042 S#3204X52131The furnace is a Carrier Model#58CMR. This is my complete system installed new back in 2004.Today I went to turn on the breaker to work the A/C and set the thermostat the inside blower turned on, as it supposed to also the condensor/ and compressor turned on as well like it supposed to, however it is short cycling.
I have tested the fan it is ok, I am going to borrow some A/C guages to test pressure. All the electrical wiring is good and tests good nothing corroded or loose. What else should I check? What could the problem be? Also I noticed with the condensor unit breaker off and the thermostat on I hear a buzzzing not sure if its from the compressor or capacitor any help is appreciated last I checked I had liquid line pressure at 168 psig, saturation tempature for measured pressure is 59 degrees, liquid line tempature is 70 degrunning R-410A. Outdoor dry bulb52 deg.
Johnson Controls Serial Number Nomenclature Examples In Excel
Ratingwhat kindby: donwhat kind of central air unit do I have?I have found it was manufactured at evcon industries in Whichita KS.the model # is BPCH0361BAthe serial # is 950551606can someone help me to find out what type of unit I have so I can cool my home. I think the blower is weak and was gonna try to replace it. Its with a 1996 mobile home 16 x 80 and unless the rooms are the ones close to the unit it just doesnt put much air through the vents. The air is cool but just doesnt blow out with enough force to do any good and the duct work is all in tact so this is may be the problem.I just need to figure out what I have in order to get one for it. Can someone please tell me or guide me to a site that can answer this by entering these numbers I have located.thank you in advance for whatever help you can provide me with.